Off-Grid Solar Inverter 3KW ~ 8KW

Off-Grid Solar Inverter 3KW ~ 8KW

Characteristics

  • Independent MPPT control microprocessor system
  • Independent inverter control microprocessor system featured with high-speed online stabilization
  • Advanced SPWM technology, high-speed power MOS
  • MPPT control using PWM technology enable to bear the maximum PV open-circuit voltage
  • Operating mode selectable: PV priority or utility power priority
  • Charging current selectable according to configured battery
  • AC input with effective online synchronous stabilization technology
  • Auto-tracking mains phase to ensure that inverter output voltage has same phase with utility voltage, reducing transfer time and peak surge
  • No-load auto shutdown function (optional)
  • Automatic frequency selection

● Auto Power-On/Off function; real-time monitoring, test and intelligent startup / shutdown by RS232 or USB interface communicating with PC; remote monitoring by optional SNMP networks

Technical Specification

MODEL

GF3000

GF4000

GF3000

GF5000

GF6000

GF8000

Rated power

3 kW

4 kW

3 kW

5 kW

6 kW

8 kW

Battery voltage

96 Vdc

192 Vdc

Operating mode

PV priority / AC priority

PV INPUT

Input voltage range

96 ~ 200 Vdc

192 ~ 400 Vdc

Max. charging current

10 ~ 60 A (selectable)

10 ~ 40 A (selectable)

10 ~ 60 A (selectable)

Optimum operating voltage (Vmp)

120 ~ 142 Vdc

240 ~ 284 Vdc

Max. PV power (Pmax)

5760 W

7680 W

11520 W

Max. conversion efficiency

98%

AC INPUT

Input voltage

165 ~ 275 Vac

Input frequency

40 ~ 70 Hz (overclocking: auto transfer to DC power supply)

Output voltage

220 Vac ± 5%

Input power factor

≥ 0.8

Max. efficiency

88% (online mode)

Max. charging current

8 A

12 A

Short circuit

Current-limiting, transfer to bypass; air circuit-breaker

INVERTER OUTPUT

Output voltage

220 Vac ± 5%

Output frequency

50 Hz / 60 Hz ± 1% (auto-sense)

Waveform

Sinusoidal

Output power factor

1

Waveform distortion

≤ 5% (linear load)

Transfer time (PV – AC)

0 ms

Max. efficiency

92%

Short circuit

Current-limiting, transfer to bypass or system auto shutdown

ALARMS

Utility power abnormal

4 s per beep , auto mute in 40 s

Low battery

0.2 s per beep

Overload

1 s per beep

COMMUNICATIONS

Communication interface

RS232, USB, RS485, SNMP (optional)

Dry contacts

PV fault, low battery, overload, bypass, inverter fault, generator ON / OFF

OTHERS

Overload protections

110% for 255 s; 125% for 60 s; 150% for 10 s

Wiring

Terminal blocks

EMI

EN62040-2:2006; EN61000-3-2:2006; EN61000-3-3:2008

IP rating

IP20

Ambient temperature

0℃ ~ 40℃

Relative humidity

10% ~ 90% (non-condensing)

Noise

≤ 50 dB

Operating altitude

2000 m (derating 1% for each additional 100 m)

Dimensions (W × D × H) (mm)

265 × 560 × 725

Packaged dimensions (W × D × H) (mm)

360 × 662 × 905

Net weight (kg)

76

80

60

67

69

85

Gross weight (kg)

85

89

69

76

78

94

 

  • All specifications subject to change without notice.